Contec 12 Channel Digital Electrocardiograph ECG1212G
$49.59
$95.21
Contec 12 Channel Digital Electrocardiograph ECG1212G The device is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in auto / manual mode; measuring, analyzing and diagnosing ECG waveform parameters automatically; prompting for “Lead off” and “Lack of paper”; optional interface language (Chinese / English, etc.); built-in lithium battery, AC / DC; selecting rhythm lead freely to observe abnormal heart rhythm; case database management. Input mode: floating and defibrillation protection Lead: standard 12-lead Patient leak current: < 10 µA Input impedance: ≥ 2.5 MΩ Frequency response: Nominal input amplitude Input frequency and waveform Relative output response 1.0 0.67 Hz ~ 40 Hz, sinusoidal ±10 %a 0.5 40 Hz ~ 100 Hz, sinusoidal 10 %, -30 %a 0.25 100 Hz ~ 150 Hz, sinusoidal 10 %, -30 %a 0.5 150 Hz ~ 500 Hz, sinusoidal 10 %, -100 %a 1.5 ≤1 Hz ,200 ms, triangular 0 %, -10 %b a relative to 10 Hz output b relative to 200 ms output The time constant: ≥ 3.2 s CMRR: > 105 dB Filter: power frequency (AC 50 / 60 Hz), EMG (25 Hz / 35 Hz (-3 dB)) and baseline drift Recording mode: thermal printing system Paper size: 210 mm (W) × 20 m (L), high-speed thermal paper Paper speed: 12.5 mm/s, 25 mm/s, 50 mm/s, error: ± 5 % Gain (sensitivity): 5, 10, 20 mm / mV, accuracy: ± 2 % Standard sensitivity: 10 mm/mV ± 0.2 mm/mV Record mode: auto, rhythm and manual record Measurement parameters: HR, P – R interval, P Duration, QRS Duration, T Duration, Q – T interval, Q – Tc, P Axis, QRS Axis, T Axis, R (V5) amplitude, S (V1) amplitude, R (V5) S (V1) amplitude Safety class: class I, defibrillation-proof type CF applied part Polarizing voltage: ± 610 mV Noise level: ≤ 12 µVp-p Sampling frequency for ECG signal input: 32 kHz Sampling frequency for waveform data processing: 1 kHz Sampling accuracy: 24 – bit Minimum detection signal: a 10 Hz, 20 µV (peak – peak value) sinusoidal signal can yield a visual recorded deflection. Pacemaker detection channel: II Accuracy of input signal reproduction: ± 5 % Amplitude quantization: ≤ 5µV/LSB Time deviation in each channel: <100 µs Power supply: AC: 100V ~ 240V (50 / 60 Hz) DC: 14.8 V / 5200 mAh rechargeable lithium battery Degree of protection against ingress of liquid: IPX0 Working mode: continuous operation Accessories Standard: One lead cable One limb electrode One chest electrode One thermal recording paper One power cord One earth wire One User Manual Physical characteristic Operating: a) Environment temperature: 5 ℃ ~ 40 ℃ b) Relative humidity: 25 % ~ 95 % (non – condensing) c) Atmospheric pressure: 700 hPa ~ 1060 hPa Transport and storage: a) Environment temperature: – 20 ℃ ~ 55 ℃ b) Relative humidity: ≤ 95 % c) Atmospheric pressure: 500 hPa ~ 1060 hPa Dimension: 340 mm (L) × 320 mm (W) × 86 mm (H) Weight: 5 kg
Digital Ecg Machine